Pulse Oximeter,OLED Show Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cowl
Original price was: $29.99.$19.99Current price is: $19.99.
Worth: $29.99 - $19.99
(as of Nov 23, 2024 12:02:53 UTC – Particulars)
From the model
AMEMO: Within the title of affection, we shield each dwelling.
Within the fast-paced fashionable life, well being has grow to be probably the most valuable asset for everybody. Nevertheless, our busy lives usually make us neglect our bodily well-being. It’s with this perception that AMEMO was born, decided to grow to be an indispensable guardian of well being in each family.
Amemo Pulse Oximeter
Product Dimensions : 2.2 x 1.2 x 1.5 inches; 3.35 ounces
Batteries : 2 AAA batteries required. (included)
Date First Accessible : July 7, 2020
Producer : SHENZHEN AEON TECHNOLOGY CO.,LTD
ASIN : B083JT4S8V
Nation of Origin : China
✅【As exact as specialised medical equipment】This oximeter incorporates a medical-grade sensor made in Japan, a high-speed processor, and clever algorithms to make sure that the measurement outcomes are as correct as these from skilled devices utilized in hospitals. Please seek advice from the introduction video of this oximeter for an indication evaluating its oxygen saturation monitoring outcomes with these {of professional} medical testing gear.
✅【Industrial-Grade Reliability】This oximeter is manufactured utilizing industrial-grade supplies and processes, making certain distinctive sturdiness. It has been examined for resilience towards drops from heights, water immersion, and excessive temperatures, but it continues to operate correctly. Please seek advice from the sturdiness take a look at demonstration video within the introduction video of this oximeter.
✅【Seeing is Believing】The introduction video of this pulse oximeter consists of precise comparative take a look at demonstrations and damaging take a look at demonstrations showcasing its accuracy, sturdiness, velocity, and steady monitoring alarm options. Seeing is believing, making certain you should buy a dependable product.
✅【Steady Monitoring】This pulse oximeter incorporates a particular spring-clip design mixed with inside medical grade silicone materials, making certain it stays in place. The oximeter can repeatedly monitor blood oxygen ranges and coronary heart price throughout train or whereas sleeping. Please seek advice from the clip stability demonstration within the introduction video of this pulse oximeter.
✅【Alarm Perform】This pulse oximeter permits you to set alarm values for blood oxygen and coronary heart price. It’s going to emit an alarm if the center price or blood oxygen ranges are irregular throughout train or sleep. It may be used for steady monitoring throughout train or whereas sleeping.
✅【Bigger & Brighter Display】The blood oxygen saturation monitor incorporates a 1.2-inch OLED show, bigger than different 0.9-inch screens, with larger brightness and extra vivid colours, making certain that the aged can simply learn measurement information.
✅【One-Key Setup】This oximeter solely requires one button to set the blood oxygen/coronary heart price alarm thresholds. 【Setup Technique】 Press the fingertip button on the oximeter to show it on, then long-press the button for two seconds to enter the settings web page. Vital Notice: Lengthy-press for two seconds to go to the following web page or make a setting; short-press to maneuver to the following merchandise. Consult with the Setup Demo within the introduction video of this pulse oximeter.
✅【Visible Knowledge, Quick Measurement, Auto Shutdown】The heart beat oximeter fingertip supplies real-time readings: blood oxygen saturation (SpO2), pulse price per minute (PR), pulse depth degree (PI), pulse waveform indicator, pulse indicator, and battery degree. Underneath regular circumstances, the oximeter can present take a look at outcomes for blood oxygen and coronary heart price in as little as 3 seconds.
✅【Packaging Contents & After-Gross sales Service】The bundle features a pulse oximeter, carrying case, two batteries (please seek advice from the constructive and unfavorable indicators for proper battery set up), lanyard, and consumer guide. –When you’ve got any questions, please be at liberty to contact us through Amazon Messaging at any time.
Clients say
Clients just like the performance, ease of use, and accuracy of the blood oxygen monitor. They point out it really works nicely, is reliable, and rapidly. Some respect its velocity, compactness, and brightness. Nevertheless, some clients disagree on the construct high quality.
AI-generated from the textual content of buyer critiques
8 reviews for Pulse Oximeter,OLED Show Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cowl
Add a review
Original price was: $29.99.$19.99Current price is: $19.99.
Abbe –
A useful conventional pulse oximeter for non-medical purposes
TL ; DNR – model A310 of OEM manufacturer Aeon Technology ; – FDA-cleared dual probe (red/near-IR) pulse oximeter ; – has EU’s CE mark and a TÃV SÃD’s certification for it ; – has ± 3% RMS-error accuracy & 1% SpO2 resolution ; – acceptable precision of 2% or less repeatability error ; – minimum 25-30 sec measuring time for reliable data. __ # 1. UPDATE (July 2022). Before the start of the CoV2 pandemic, I got this device to monitor the amount of oxygen carried by my red blood cells when at 1500m or more, elevations at which not only the reduction of oxygen’s partial pressure starts to affect my body, but also can take a long time to adjust to it when coming from ~300ft above sea. Nevertheless, with the pandemic’s arrival, the device had a steady routine use at home over the last two and a half years with no issues. For mountaineering purposes, it has been tested on a Pic Anetoâs couloir gig in 2022 and worked very well. I’m satisfied with it. # 2. DEVICE. This type of conventional pulse oximeter [ PO ], based on light pulses from red and near-IR LEDs used in a transmission configuration, has been adopted as a routine non-invasive, indirect method for estimating the fractional oxygen saturation, SpO2, which indicates how much functional hemoglobin is bound to oxygen compared to how much of it is unbound. It is established technology, so the conventional POs, despite their range of prices, are nearly identical in function, and, if reasonably well designed, provide similar data. Not only higher prices do not necessarily translate into higher accuracy, but also a manufacturerâs claim that its own signal processing method (DSP, SET, etc) was found to be better in a given clinical study is often negated by other study results. A good rule of thumb in selecting a PO is to search if its model is indeed listed as cleared in the FDA’s “510(K) Premarket Notification” database, which requires data submission to FDA to demonstrate that the device is safe and effective. # 3. SOURCE. This device is the model A310 (and not A310L, as still stated in the Product Description section of this page) of the OEM manufacturer Aeon Technology Co. Ltd. (Shenzhen, China). The A310 available here is distributed by Amemo Inc. (Milpitas, CA), and sold by the storefront of the Tianyi Star Aviation Technology Co. Ltd. (Beijing, China). The seller’s claim in a reply of the Q&A section, that they “recently discovered that other companies sell this product” is a non-sense sales pitch as they, like the other retailers of the OEM A310, buy it from Aeon Technology. # 4. VALIDATION. The A310 is FDA approved. Under the orange silicone cover of the base it has a sticker with the serial number, and a âCE 0123â approval mark showing that its CE mark (assuring conformity with EUâs health and safety protection standards) is certified by the German company Tüv Süd, in whose database the Aeonâs certificates can be found. (This has validity value, since in March 2022, 11 of 15 POs, bought from Amazon and other online platforms, and tested by the UKâs consumer website âWhich?â failed to comply with the CE regulations.) # 5. SPECS. The device measures SpO2, heart rate [ PR ], and the so-called perfusion index [ PI ], the ratio of pulsatile to non-pulsatile blood flow. Be aware that the specs in the Product Description section of this page, at the time of this update still do **not** conform to those in the A310 user manual (v.2 March 2020) or the 510(k) application to the FDA, particularly in SpO2% accuracy. The device has the following specs — Display Range: SpO2 35-100%; PR 30-250 bpm; PI 0-20 % (can reach ca. 30% during unstable initial phase) / Accuracy: ±3% for SpO2% between 70 and 100 (unspecified if less); ±1 bpm PR; ±0.1% for PI% of 0 to 1 and ±1% for PI% of 1 to 20 / Resolution: 1% SpO2; 1 bpm PR; 0.1% PI. # 6. ACCURACY. PO manufacturers typically claim an accuracy in the ±1 to ±3 range, which is a laboratory estimate using the root mean square error. But that is a statistic –often referred to as A(rms)– based on the standard deviation of differences between simultaneously measured SpO2 data and directly-read arterial data in healthy subjects, combining data dispersion and offset under highly controlled conditions. Of course, that does not happen in at-home measurements, which is why claims of high accuracy are meaningless for non clinical or lab use. Given the 95 % or higher oxygenation of arterial blood in healthy people, their SpO2% values can be expected within the 93 to 100 range because of the associated errors of the PO technique as well as the normal variation of arterial oxygenation in a single subject and among subjects. # 7. PRECISON. In addition to how close is a PO reading to the value in arterial blood (i.e., accuracy), one needs to consider how close to one another are repeated readings (i.e., precision) — keep in mind the latter is independent of the former. Repeatability differences are evident in my attached figure ploting SpO2% [top] and PI% [bottom] data collected every 5 minutes from my left thumb (after 30 seconds from inserting the finger and turning on the device); in each plot, the respective mean value is shown by a solid line, and the standard deviation limits by dotted lines. While the sample is only 16 repetitions, the data suggest a repeatability of ±2% or less. Always repeat at-home PO measurements — do not miss the oximetric forest for the trees. # 8. MEASURING ISSUES. (a) Selecting a routine target finger — There is published evidence that oximetry provides different percentages in the same person depending on the selected finger. A small study of right-hand dominant, healthy subjects not wearing nail polish concluded that the right thumb and middle finger yielded the statistically highest SpO2. However, you ought to determine your best finger for PO, as this can vary; I have mixed handedness and my left thumb consistently yields the highest values, followed by the right one and the middle finger of both hands. This is shown in my other attached figure, where after normal full (rather than deep) breaths over 30 seconds, the SpO2 readings were taken 15 and 30 seconds after turning on the device — the fingers were measured in a non-sequential manner with a 2-minute resting period between tests. (b) Measuring time — SpO2 readings can vary initially till the device becomes relatively stable, typically within the first minute. Use the plethysmograph (the yellow vertical display on the screenâs right margin) as a guide for accepting SpO2% data once the waveforms are distinctly formed and their amplitude is consistent (in this condition, the PI% should be higher than 1, rather than 0.2). This is likely the only advantage, unless you are a physician or trained nurse, of having a waveform display of how blood volume changes with heart beats. Disregard the recommendation of Amemo in this webpage of “press the operating button, and then wait. Within 10 seconds, youâll have an accurate reading of you SpO2 levels and pulse rate.” That is FALSE. It takes at least some 10 to 15 seconds for all three measurements to appear in the display (PI is the first and SpO2 the last), and then readings begin to stabilize at least another 10 to 15 seconds later. (c). External error sources — POs yield inaccurate data under a number of conditions. The main known causes are motion artifacts (hand movement, PO slippage), cold fingers, anemia, direct sunlight or bright ambient lights, mechanical-force pulsations from nearby arteries, pulsatile variations of tissue thickness in the light path other than in the arteries, nail polish, and some degrees of skin pigmentation. It is a long list and you should run a search to see if there is a type of error that may systematically affect PO readings in your case.___
Lynn Russell –
Convenient, Accurate and Easy to Use
Being unsure what to order, I ordered two – this brand plus another one with high ratings that cost almost twice as much. I was quite surprised at how much better this one was. I was going to keep the more expensive one and give the other to a neighbor. Instead, I gave the other away and kept this one! Also, this one shipped promptly and came with a case. The other took two weeks and had no case. This also features a third reading, which the other did not. All in all, I found this to be a great value!
JerBer –
Very compact
Works great
review by w –
Good Value Oximeter with Perfusion index.
This is a review of the Pulse Oximeter model A310 by Shenzhen Aeon Technology.Overall seems to be of decent quality. Comes with lanyard, silicon skin, case and AAA batteries. Besides the standard oxygen and pulse rate, this has a perfusion index, as a percentage and a graph, to indicate if your heartbeat is normal.Gives me consistent readings on my fingers and 1 toe that I tried. Takes about 5 seconds for initial reading and another 4 or 5 seconds to get a stable reading.The only downside to this meter is the display, as it is small. It is also fixed in the portrait position, the display doesn’t rotate into a landscape position as you rotate the meter. The OLED display has excellent contrast & brightness, so reading the numbers isn’t hard for me.Instruction manual is extensive and relatively well-written. No mention of warranty, service or contact information, so if it starts malfunctioning 6 months down the road, you probably have no recourse.Would buy again.
Aubrey whittington –
Pulse oximeter
Works great. Been using it and I like it very much I use it for my work
Edward Brunell –
What
Ok
Dovey739 –
Nice Instrument
Easy to use and read. Also provides perfusion index which is generally on more expensive instruments. The wife has asthma, and this is good to have on hand. Also low oxygen levels are an early indication of possible Covid19. The earlier it is detected, the better, since testing has not been readily available and results prompt. The price was reasonable and delivery prompt. A good buy.
bert –
easy to use
Although the display is a little small, it is easy to read. The O2 level matches what i have in hospital and pulmonologist office, so it seems accurate. Came with a nice soft skin-case and fabric pouch, lanyard and batteries. Seems well worth the price. Open little box, unwrap and install two batteries, pop onto finger, and off you go.