Generator Interlock Equipment Suitable with Sq. D QO or Homeline 150 or 200 amp Panels.1 3/8 inches Spacing Between Most important and Generator Breaker.Skilled and Interlock Equipment(1set)
$17.99
Worth: $17.99
(as of Jan 19, 2025 09:55:47 UTC – Particulars)
From the model
QYZZRS Generator lnterlock Equipment
QYZZRS Skilled Generator lnterlock Equipment Provider.Broadly present lnterlock equipment appropriate with a lot of the fashions of breaker panel
Protected & Dependable Sensible
With Our QYZZRS Interlock Equipment, you may safely again feed electrical energy into your house out of your electrical panel and moveable generator.
Different fashions interlock equipment
Different fashions interlock equipment
Different fashions interlock equipment
Different fashions interlock equipment
Different fashions interlock equipment
Different fashions interlock equipment
Different fashions interlock equipment
Product Dimensions : 2.75 x 2.97 x 0.06 inches; 1 Kilos
Merchandise mannequin quantity : DDA-01
Date First Obtainable : February 7, 2023
Producer : QYZZRS
ASIN : B0BV31CJMM
Nation of Origin : China
Generator interlock kits can be found for Sq. D QO and Homeline 150 and 200 amp panels.
Interval House Required:1 3/8 Inch Spacing between fundamental and generator breaker.
Set up Notice: Earlier than putting in the interlocking equipment, Connect the screws to the interlock equipment first. Let’s simulate using the check, in order that we will higher align the set up place, to keep away from errors within the set up place, leading to failure to make use of.
Protected use:the guide switch change system permit moveable generator secure again feeding energy provide to distribution panel and residential line. Stop utility and generator provides from being ON on the identical time. Aren’t placing electrician in harmful and harm electrical gadgets throughout energy outages.
Bundle:Our Generator Interlock equipment embody 1 × Interlock plate, 3 × Screws equipment, 1 × Drill Bit, 1 × Instruction Bulletin, 2 × Generator Begin-Up Process Label, 8 × Remind Label, 2 × Zip Ties.
Prospects say
Prospects discover the circuit breaker useful, well-made, and fairly priced. They recognize its security options and good match. Nonetheless, some dislike its thickness and have blended opinions on set up ease.
AI-generated from the textual content of buyer critiques
10 reviews for Generator Interlock Equipment Suitable with Sq. D QO or Homeline 150 or 200 amp Panels.1 3/8 inches Spacing Between Most important and Generator Breaker.Skilled and Interlock Equipment(1set)
Add a review
$17.99
S. Mayo –
Requires Thoughtful Installation
Clever device to positively isolate generator from utility power during operation. Should be installed by qualified electrician. Needs 1 open 2-pole space for generator breaker (not supplied). Main breaker must be turned off for proper installation. Includes clear instructions and labels for operation after installation. Can be installed when Main Breaker is at the bottom of the panel – like mine is. Good economical alternative to a transfer switch.
Al –
Perfect fit
This interlock switch was a breeze to install and works exactly as it should. Perfect.
Larry in FL –
Worked well except for an additional internal interlock
This seemed to be a quality kit and it was easy to install; the template was correct for my Square-D QO box. My kit came with an additional piece that was supposed to install inside the box, behind the panel, to hold down the critical breaker, but that piece did not fit. That was Ok, as I don’t see the need for it anyway! And it looks like the kit now no longer includes that piece anyway!
Felipe Estrada –
Square D QO Interlock Installed
Thin metal plates is the only downside.Could have been a thicker gauge.But it works as expected when installed correctly.Prevents back feeding power into main.* Make sure you buy the correct interlock for your fuse panel.Iâm no electrician, but the install was smooth.
Pirate guy –
Great value and well made!
Kit contains everything you need (except the breaker and a drill of course). It also contains stickers to properly label the new breaker. I didnât fully understand how these interlocks are installed when I ordered it but it wasnât hard to figure out. On my box, it could only be installed in one particular location next to the main panel on/off switch and only on the left buss bar (on my panel, located at the bottom). So I had to remove two knock outs at the top of the panel and move the existing 240v breaker to that position. Obviously, that involves rerouting the wiring too. Then install the new generator breaker next to the main shutoff. Obviously, these instructions are not complete. I just want to give you a general idea whatâs involved so youâll know whether or not this a DIY project for you or if you will need a pro (never a bad idea!).
TOBY GEORGE –
Must have to meet code
This kit is simple and easy to use. The added warning and caution â ï¸ labels are a plus.When connecting a generator to your home electrical panel, you need a safety interlock kit. There are lots of âDYIâ videos out there to fabricate one, however I felt like this one would be safer to meet code. Even though my panel was installed inverted with main breaker at the bottom (new home construction, lack-luster electricians). It still fit well.This fits a Square D QO PANEL ONLY.
Amazon Customer –
Generator panel safety switch
Worked as described, installed like it was supposed to Worked like it should
pat –
Fit correctly
Easy to install
884798 –
Ce produit me satisfait a100%, bonne qualité.
Stephen –
Item came on time and is very easy to install. Provides safe cut off of power to grid, when utilizing a generator during a power outage. Instructions were clear and concise, and there are many YouTube videos that assist in installing these types of safety devices. Would recommend to anyone living in areas where power interruptions are common.